Our detection method: Fast, simple, and reliable

A method designed for the field, from sampling to result, in under 90 minutes.

A 5-step method for environmental monitoring

1

Sampling

Swab

Suited to both flat surfaces and hard-to-reach areas (corners, joints, equipment). Sampling follows your environmental monitoring plan.

2

Lysis

LoopiX

The LoopiX acts as a heating block, to release the genetic material contained in the sample collected.

3

Purification

PurifiX

Purification of the genetic material and removal of inhibitors, for a reliable, actionable result.

The PurifiX range offers different solutions, tailored to your needs.

4

Amplification

LoopiX

LoopiX automates the target genetic material amplification phase using RT-LAMP technology.

5

Result

LoopiX

Absent / present result displayed directly on the LoopiX.

Traceability ensured by a dedicated, intuitive, and secure tool.

Why this method?

Gain responsiveness

90 minutes from sampling to result, versus 24 to 72h with conventional methods

A faster result allows you to:

  • React and trigger corrective actions as early as possible.
  • Limit the consequences of contamination.
  • Block product distribution to avoid a product recall and the associated extra costs.
Cut the cost of non-quality

Trustworthy results for an optimized process

A reliable, fast result allows you to:

  • Limit storage costs while waiting for results.
  • Avoid the extra costs of non-quality (recall, logistics, destruction, …)
  • Protect your brand image and your company.
  • Adjust and control your cleaning protocols based on your environment and risks.
Adapt to your needs

An on-site, easy-to-master solution

Easily deployed on-site directly by your teams, this added control allows you to:

  • Decide the timing and frequency of your analyses.
  • Adapt analyses to the risk level, depending on zones and periods.
  • Define control points across your production environment, down to the smallest corners.
Logo AOAC PTM - 082603 - Listeria monocytogenes

Reliability certified AOAC Performance Tested Methods℠

The AOAC Research Institute is a global benchmark for independent validation of food safety methods. This certification confirms that LoopDeetect Listeria monocytogenes performance meets the industry’s most demanding standards.

Speed

On-site

Reliability

LoopDeetect Listeria monocytogenes is certified AOAC Performance Tested Methods℠ 082603.

The certification covers protocols with and without enrichment; find all the information about the certification here.

Discover our 3 solutions

Lysis & amplification device

The lysis and amplification tool, at the heart of your detection process.

Purification solutions

The purification range that removes inhibitors for reliable results.

Analysis reagents

The analysis reagent range, for on-site pathogen detection.

Frequently asked questions about our LoopDeetect method

The AOAC Performance Tested Methods℠ is an independent certification program from the AOAC Research Institute, a global benchmark for validating food safety methods. It guarantees that a method’s performance has been evaluated using rigorous protocols, benchmarked against the industry’s reference methods.

Our LoopDeetect method is AOAC PTM certified for the Listeria monocytogenes protocol without enrichment. This means this method, which is simple to use in the field and requires no specific expertise, delivers the same performance as reference methods, with results in under 90 minutes.

Find all the information about our AOAC PTM certification here.

Our method is positioned as a complement to conventional microbiological analysis methods. It’s a genuine decision-support and rapid screening tool, allowing you to react immediately in the event of a positive result, before laboratory confirmation if needed.

Unlike conventional culture methods (48 to 72h), our RT-LAMP technology delivers a result in 90 minutes maximum. Unlike conventional PCR, which requires a thermocycler and precise temperature cycles, RT-LAMP operates at a constant temperature, making it simpler to deploy directly on-site.

Yes. Designed for pathogen detection in the production environment, our solution deploys directly on-site, with no dedicated lab infrastructure required — a genuine field solution for your quality teams.

Our solutions support players in the food processing, feed, and pet food industries in their industrial food safety approach.

Check out our case study with Norwegian Seafood.

90 minutes maximum, from sampling to an actionable result on an environmental sample. A rapid pathogen detection that genuinely changes your field responsiveness.

The handling is simple and intuitive: just a few liquid transfers (only two pipetting steps with LoopiX and PurifiX8). It takes just a few hours of training to get up to speed, with no microbiology expertise required. Genuine autonomy for your quality teams in production.

The method allows the analysis of environmental samples (surfaces, equipment, hard-to-reach areas) as well as product samples, thanks to protocols specifically adapted to each matrix to ensure reliable results.

Our method fully integrates into a HACCP approach. A simple, fast tool that strengthens day-to-day quality control, helping to limit the risk of product recall and the associated health, financial, and reputational consequences.

Have a specific pathogen detection need?

Our teams will help you find the right solution for your production.